Product Thermal Capacity: 1 - 20 t/h
Working Pressure: 0.7 - 2 Mpa
Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.
1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.
2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.
3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.
4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.
The Solution. In order to prevent iron corrosion, improve boiler cleanliness and optimize overall ease of application, Veolia Water Technologies introduced ProtectAll TM as the “All-In-One” treatment for the university steam/condensate system. ProtectAll TM is a green, surface-active chemistry that selectively targets virgin metallurgies for formation of a monomolecular, hydrophobic
SUBJECT: Steam Boiler Water Treatment. This Technical Services Bulletin replaces SB0011 dated December 7, 2000. Our update is an effort to help steam boiler service professionals and end users identify an emerging issue of internal corrosion in cast iron steam boilers. Chlorides, chlorides & …
Legendary Reliability and Value, Improved for Even Higher Performance For decades, the Series 2 has been the industry benchmark for cast iron gas-fired boilers. Its time proven design blends a long lasting cast iron heat exchanger with a heavy-duty steel base and high quality boiler controls to provide exceptional value for the homeowner.
This is the best iron I have ever used!! I have had about 10 irons during my years of sewing professional sewing and this one is the best iron I have purchased, hands down!!! The steam is awesome and the temperature is spot on. I love the large water reservoir and the weight of the iron. This iron doesn't leak water, which is a pain when ironing.
Carryover of impurities from boiler water to steam is also inherent to boiler operation. Though separation devices in drum boilers remove most water droplets carried by steam, some residual droplets containing small amounts of dissolved solids always carry through with the steam. Also, at higher pressures, there is some vaporous carryover.
Whatever your needs, depend on Weil-McLain commercial boiler systems to provide a solution that delivers cost savings, energy efficiency and flexibility.
Apr 27, 2017· Heat up the iron for five minutes, and then press the steam button for 20-30 seconds repeatedly until the steam flows freely. To clear out any remaining traces of vinegar, fill the reservoir with just distilled water and run the steam function again.
Jul 17, 2017· Using tap water for your steam iron can clog the iron, making the steam sputter out or not come out at all. Regular tap water contains minerals, like calcium, that will build up inside your iron. Even with a water softener, you tap water will still contain trace amounts of …
When you purchase a residential boiler, water heater or radiator from U.S. Boiler Company, you know you're getting the best in comfort, durability and safety. Three of our current models meet the Energy Star efficiency standards. We have the right boiler for your home.
GoldStar Heavy Duty Steam Iron With Boiler. The GoldStar brand system that will bring your commercial laundry or dry cleaning service into the new millennium. This heavy duty 1000 watt steam iron with 1.8 liter boiler capacity can work in large scales, and iron for a full three hours without refilling.
The distilled water shown to the left is typically what many iron users put into their steam iron. They mix 50% of their normal tap water along with 50% of this top up De-Ionised water if they live in what is classed a "hard water area."
No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China
0086-510-68530066, +86-13506151292
Get Latest PriceCopyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.