Product Thermal Capacity: 1 - 20 t/h
Working Pressure: 0.7 - 2 Mpa
Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.
1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.
2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.
3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.
4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.
Oct 25, 2012· Oil contamination on boilers should lead to the rectification of the heat-transfer surfaces on the water and steam side prior to the boiler being put back into service. Boiling out the water side of the boiler using recommended chemicals and/or mechanical cleaning are normal procedures undertaken to facilitate satisfactory cleaning.
File Size: 1MB Hot gases from the burning oil pass through metal tubes or sections in the boiler, heating them in the process. These hot pipes in turn heat the water in the boiler up to the safe maximum temperature of the system. This water is stored in the boiler until the system is …
Jul 08, 2016· Designed for waste oil. Built for the long run. To create the perfect waste-oil recycling machine, EnergyLogic started from scratch to engineer a boiler made specifically for waste-oil & multi-fuel combustion. Our boiler is an ASME-certified true-vessel made of durable heavy-carbon steel.
Thermax Limited - Offering Thermax Shellmax Oil and Gas Boiler, थर्मैक्स गैस फायर्ड बॉयलर, Thermax Oil and Gas Fired Boiler in Shivaji Nagar, Pune, Maharashtra. Read about company. Get contact details and address| ID: 10748727788
PG 18-10 – STEAM, HEATING HOT WATER, AND September 1, 2016 OUTSIDE DISTRIBUTION SYSTEMS DESIGN MANUAL . Vol 1 ST EAM BOILERS 2 . 1.3 Boiler System Capacity:
Aug 29, 2017· Drum water filling is a very important activity before boiler light up . in boiler hydrostatic test we also filling the drum with above method but in this condition little bit variation in the process of water filling . first of all insure that the suitable D.M water level is available in deaerator after that check out healthyness of the boiler feed pump . before start up of the boiler feed
File Size: 1MB Feed-water purity requirements therefore can vary widely. A low-pressure fire-tube boiler can usually tolerate high feed-water hardness with proper treatment while virtually all impurities must be removed from water used in some modern, high-pressure boilers. Only relatively wide ranges can be given as to maximum levels of alkalis, salt, silica
Location: Thermax House, 4, Mumbai Pune Road, Shivaji Nagar, 411003 Feed Water & Boiler water Characteristics as per IS:10392-1982 1.FEED WATER Parameters Upto 20 Kg/cm2 21 Kg/cm2 to 39 Kg/cm2 40 Kg/cm2 to 59 Kg/cm2 Unit Total Hardness <10 <1.0 <0.5 ppm as CaCO 3 pH Value 8.5-9.5 8.5-9.5 8.5-9.5 Dissolved Oxygen 0.1 …
Location: No. 702, Lakhanpur Housing Society, Khyora, 208024, Kanpur Feb 10, 2018· Learn more about your oil heat hydronic heating boiler system, boilers & how it works showing hot water components zone controls & troubleshooting basics - Great for …
A boiler is an enclosed vessel in which water is heated and circulated, either as hot water or steam, to produce a source for either heat or power. A central heating plant may have one or more boilers that use gas, oil, or coal as fuel. The steam generated is used to heat buildings, provide hot water, and provide steam for cleaning, sterilizing,
Oil boilers are perfect for homes that do not have access to natural gas and can lead to huge savings by using renewable fuels. eComfort offers a comprehensive assortment of conventional & high efficiency oil boilers, along with the parts necessary for fixing or upgrading your current model.
No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China
0086-510-68530066, +86-13506151292
Get Latest PriceCopyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.