Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

1 tph steam boiler heating surface area to calculate – o

how much heating surface area of 1 ton boiler How do you calculate boiler heating surface? Boiler steam capacity 12 TPH (Type Е12-1,3-225D) 2012-9-19 · the heat loss due to blowdown should be calculated and added to the heat in steam. 1.6.3 Boiler rate Surface Temperature of boiler Surface area of boiler .5 …

Boiler Surface Area: More is not Necessarily Bett

The example also shows that you can have comparable performance even when the the total surface area varies by 9% (for each boiler, total area = sum of furnace, evaporator, economizer areas, which total 13,158 vs. 14,336 sq. ft) Also, the location of the convective superheater affects the surface area significantly. The company where I am

boiler heating surface area formula – CFBC Boiler Manufactur

I have to calculate the heating surface area. Heating Surface Area of Fire Tube Boiler 10/10/2012 1:54 PM. Hello Bro! Register to Reply: dhayanandhan. Boiler Formulas – Debco Equipment. Boiler Formulas: Common Conversion Factors. Boiler HP x 34.5 Boiler HP x.069 Boiler HP x 33.4 Boiler HP x 139 BTU/Hour Output ч 240 EDR/1000 x 0.5 Lbs of

boiler heating surface arecalculati

surface area of 4 ton boiler. 1 Ton Boiler Heating Surface Area - Selection of Heating Boilers-1 ton boiler heating surface area. excellent quality brown coal steam boiler Industrial 2018-3-2 · Coal is first milled to a fine powder, which increases the surface area and Expert systems and coal quality in power Semantic Scholar application of expert systems.

Boiler Capacity Calculation with Heating Surface Area--Z

Boiler Compoments Manufacturers in India · Power Plant Chhattisgarh Boiler · Contact Us Boiler Capacity Calculation with Heating Surface Area 2018-09-29 11:00:44. 1 ton steam boilers generate 600,000 calories of heat, according to the standard per square meter of building (residential, office, hotel, etc.) heating 100 calories, so a ton of steam boiler standard heating area of 600000 /100 = …

IBR - 1950 : Reg. 3

Reg. 383 Measurement of heating surface. a) For the purpose of regulating the area of the safety valves and the amount of registration and inspection fees the “heating surface” of a boiler shall be the total surface of all plates and tubes exposed to heat on one side and in contact with water on the other measured on the water side or the

4 ton,Peru,thermal oil boil

4 ton 2900kw gas /oil fired hot oil heater /thermal oil boiler details. 4 ton 2900kw gas /oil fired hot oil heater /thermal oil boiler details the boiler modle :YQW-2900Q hot oil /thermal oil boiler ,horizontal Energy conservation and environmental protection boiler,the boiler pressure :8bar 0.8mpa ,the boiler fuel:gas or oil fired .the boiler capacity:2900kw .our factory make 350kw ,700kw

How do you calculate heating surface of a steam boil

Jan 16, 2007· so question,, what is the heating surface area of a boiler with 21 tubes, 2.5" in diam, 16' long. the calculation will look like this. diam x pi x (16' x 12") x 21 divided by 144. 2.5 x 3.1416 x 192 x 21 divided by 144. 2.5 x 3.1416 x 192 x 21 = 31667.328 . 31667.328 divided by 144 = 219.91

boiler heating surface area formula – Industrial Boil

Heating surface area of a boiler is usually expressed in square … Determining Boiler Capacity from Heating Surface Area … Dec 10, 2004 · Determining Boiler Capacity from Heating Surface Area Determining Boiler Capacity from Heating Surface Area … but I need to convert this area into boiler … Heating surface calculations – SmokStak

What is the heating surface of a boiler according to t

hp is calculated by the blr mfr but probably have 400 to 600 hp if you calc 5 sfhs to 8 sfhs per bhp. newer boilers are squeezed to 5 or 6 sfhs/b1Steam generating capacity can be determined from heating surfaces on a FT boilers but w/WT boilers the steaming capacity determination is a littleSpirax Sarco has a module on boiler ratings and boiler horsepower in their website learning centre. Block 3, module 3.5 I think. Not too sophisticaSince Your D-type WT boiler has water-cooled metallic walls,the average heat release in the furnace is 30,000 btu/hr per cu.ft. of furnace volume fRat, How about something really approximate such as comparing outside dimensions to modern D-type boilers ? In my opinion, if I have a "box" with t Jul 02, 2018· Boiler energy balance on cooling medium side have UxAxLMTD. Here U is heat transfer co-effi., A is heating surface area and you know LMTD. U and LMTD varies with boiler operating parameters like operating pressure, steam temp., gas temp., gas velo

What is the capacity of a boiler if its heating surfa

Jun 03, 2018· Assume boiler with dimensions 10 x 10 x 20 surface is 10 x 10 x 2 = 200 and 10 x 20 x 4 = 800 total 1000 SM volume is 10 x 10 x 20 = 2000 M^3

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration