exhaust gas boiler unit himsen 9h21 32

Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

Exhaust Gas Boiler on Ships - Marine Engineeri

Dec 09, 2015· In emergency mode the exhaust gas boiler can therefore be operated with low water level and even without water with the full exhaust gas flow through the boiler tubes, provided the boiler is operated depressurised and the inside temperature does not exceed 400˚C. For inside inspection, the boiler is arranged with both hand holes and manholes.

Himsen H21/32 diesel engine charge air cooler - YouTu

Jan 03, 2013· Vestas aircoil replacement cooler at our factory in Denmark. For the Love of Physics - Walter Lewin - May 16, 2011 - Duration: 1:01:26. Lectures by Walter Lewin.

New 8505kW Hyundai HiMSEN HFO Generat

Supply of 8.505MW HFO Containerized PPS USP&E diesel engine generating sets producing 1,701kW each at generator terminal (Packaged Power Station Type). Prime mover is Hyundai HiMSEN 9H21/32 model having its capacity of 1,800kW at engine crankshaft end. One (1) Common Exhaust Gas boiler system covering (5) engines each for fuel heating only.

HiMSEN Propulsion Engine - doczz.n

LNG Tank Booster Pump ( LP ) Application HP Pump ( HP ) Vaporizer ( HP ) & G/W Heating system Gas Train Buffer Tank Gas Heater GVU (Gas Valve Unit) ME-GI HiMSEN DF Genset HHI-EMD can supply complete LNG package solutions for LNG carriers and LNG-fuelled ships. 24 www.hyundai-engine.com 25 ECO / TURBO MACHINERY NoNOx(SCR) System HYUNDAI TM SCR

New 51030kW Hyundai HiMSEN HFO Generat

Supply of 51MW HFO Containerized PPS USP&E diesel engine generating sets producing 1,701kW each at generator terminal (Packaged Power Station Type). Prime mover is Hyundai HiMSEN 9H21/32 model having its capacity of 1,800kW at engine crankshaft end. Two (2) Common Exhaust Gas boiler system covering (30) engines each for fuel heating only.

Diesel Exhaust G

Jan 01, 2018· Shown are temperatures from vehicle chassis dynamometer certification cycles (cold start FTP 75 and US06) and a heavy-duty engine dynamometer certification cycle ().The T 90, T 50, and T 10 values are defined as temperatures below which exhaust gas temperature is 90%, 50%, and 10% of the time, respectively. Also shown is the time, t 200°C, from the cycle start to the point where exhaust gas

Direct Exhaust Venting Kit Instructions - Weil-McLa

Direct Exhaust Venting Kit Instructions Evergreen® 220/299/300/399 — Kit part number 383-500-769 You must read and have the Evergreen® boiler manual with you to proceed with these in-structions. Follow all instructions in this instruction and the Evergreen® boiler manual to access and service components. The parts provided in

Reasons for High Exhast Gas Temperature (EGT) in Mari

Exhaust gas is by-product of combustion and is naturally at a high temperature. But there is a limit to the diesel engine exhaust gas temperature, and it should not exceed the manufacturer's stated values. Learn what problems can cause this rise in exhaust gas temperature in order to enable troubleshooting and so that taking care of these factors results in restoring normal temperatures.

Exhaust Gas Steam Boiler - Lars Josefss

Exhaust Gas Boilers also known as Exhaust Gas Economizers, with extended heating surface, used for waste heat recovery in motor ships. A diesel engine loses approximately 30% of the energy to the exhaust gases. A turbocharger recover some of it, but there is still heat losses that can be recovered by means of an Exhaust Gas Boiler, EGB.

Alfa Laval - Exhaust gas economiz

Exhaust gas economizers after diesel engines and waste heat recovery units after gas turbines are unfired and utilize the otherwise wasted heat from the exhaust gas of the diesel engine/gas turbine to produce energy/heating. Request information Request information for Exhaust gas economizer. Contact subject. Request a quote Request product

Boiler Stainless Steel Exhaust Flue Stack | HVAC Heati

Boiler Stainless Steel Exhaust Flue Stack: This is a photo of a boiler stainless steel exhaust stack. It is used for venting corrosive boiler combustion gases. As the flue gases leave the boiler they cool and depending on the dew point of the gas the gas will experience a change of state.

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration

Copyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.

top