Product Thermal Capacity: 1 - 20 t/h
Working Pressure: 0.7 - 2 Mpa
Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.
1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.
2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.
3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.
4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.
Keystoker KA-6 Operation Guide.Nov 24, 2018Difference between a Keystoker KA6 and KFAFeb 25, 2018Difference between a Keystoker KA6 and KFA | Stoker CoalNov 15, 2017Keystoker KA-6 Feed | Stoker Coal Boilers Using AnthraciteDec 31, 2010See more results In short, lower Btu coal will increase the pounds of coal to be handled and when the variations are large enough we can expect a reduction in boiler capacity. Higher Btu coal seldom gives any pro- blems in boiler operation or performance. See Figure 1 for typical …
Installation and Operating Manual for the EFM Wood/Coal Boiler Model WCB EFM Sales Company Emmaus, PA 18049 Coal 1. The WCB Boiler is designed to burn operation of the boiler. The chimney should be masonry with tile lining (8" x 8" x 15 ft. high) or
Author: The Practical Study Engineering Boiler Operation Standard Procedure: The main purpose of the Boiler operation SOP is to ensure that the hotel boiler is maintained in excellent conditions and hot water supply is available to all guest rooms and public areas.. 1) Fill the feed water in the coil with the help of feed water pump till the time water comes out of the by-pass line.
Apr 09, 2018· As the coal is initially milled to a fine powder to be pulverized and then burnt in a furnace (combustion chamber of a boiler); and we use the heat energy released to heat water into super-hot steam which under high pressure and temperature used to turn the turbines connected to electrical generators by a shaft which then drive the generators
installation and operator’s manual commercial applications coal gun™ boiler models: s260, s500, s1000 important: in order to achieve safe and satisfactory results from your alternate heating systems, inc. boiler, read safety rules and instructions carefully before installing and operating. all installations must be in
The surface condenser is a critical component in the operation of a steam power plant. Condenser failures can result in forced outages and loss of generation capacity. TEi condensers represent an evolution of advanced technology, offering improved thermal efficiency and advanced mechanical design to reduce forced outages and increase availability.
Operating guidelines, loading tips and maintenance recommendations for your outdoor furnace.
Boiler Operation and Maintenance. Proper operation and maintenance of your boiler and its distribution system can save significantly on energy bills. Since many boiler systems operate at an average efficiency of only 65 to 75%, the remainder of your heating fuel bill is going up the chimney or down the drain.
May 1981 EPA-600/8-81-016 A GUIDE TO CLEAN AND EFFICIENT OPERATION OF COAL-STOKER-FIRED BOILERS Guidelines intended for use: - by personnel responsible for boiler operation to perform an efficiency and emissions tune-up - by plant engineers to initiate maintenance and efficiency monitoring practices - as a supplement to manufacturer's service instructions American Boiler Manufacturers
Sep 24, 2013· Stoker Coal Boiler: KEYSTOKER Kaa-2 Hand Fed Coal Stove: Hitzer 50-93 & 30-95, Vigilant (pre-2310), D.S. 1600 Circulator Post by oliver power » Mon. Feb. 04, 2013 1:35 pm
stoker unit equipped with a coal hopper that held enough fuel for several days. This allowed the coal to be cleanly burned and without frequent maintenance. They then saw the need to make a hot water boiler specifically designed to burn coal and built them in multiple sizes to meet our customers' needs.
No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China
0086-510-68530066, +86-13506151292
Get Latest PriceCopyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.