Product Thermal Capacity: 1 - 20 t/h
Working Pressure: 0.7 - 2 Mpa
Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.
1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.
2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.
3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.
4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.
User rating: 3.7/5 Oct 22, 2007· You’re sort of right. Above 212°F at standard pressure, liquid water is unstable. It will evaporate very rapidly from the surface. If the temperature is held constant (which requires some heat input, since evaporation cools things) the liquid will all evaporate. If the temperature is much above 212°F, the water will boil.
Related Topics . Steam and Condensate - Steam & condensate systems- properties, capacities, pipe sizing, systems configuration and more; Related Documents . ASME - International Boiler and Pressure Vessel Code - The International Boiler and Pressure Vessel Code establishes rules of safety governing the design, fabrication, and inspection of boilers and pressure vessels, and nuclear power plant
On the 10-degree day the temperature will be 180 degrees, but on the 40-degree day the boiler water temperature automatically lowers to just 135 degrees. Option A – Partial Reset Unfortunately a standard boiler will be damaged if it is allowed to continuously operate at temperature below 140 degrees, so a standard boiler has a minimum
What pressure should my boiler be? Generally, your boiler pressure should be between 1 and 2 bar. However, read your boiler’s manual or ask your heating engineer for the required pressure for your particular model. To check your boiler’s pressure, you need to locate the pressure gauge on your boiler.
Proper Boiler Feed Water Temperature Management Prior to it entering the boiler, the plant manager has the opportunity to control both the boiler feed water temperature as well as its quality. This involves introducing treatment and heating that will provide optimal conditions for a long boiler life.
Test your tap water temperature. Allow the water to run until it is fully hot and fill up a tall glass. Hold a cooking thermometer in the water and take a temperature reading. The water should be a minimum of 120 degrees Fahrenheit. If it is less, adjust your hot water boiler upwards.
Oct 13, 2016· When the boiler is equipped with hand operated, main steam stop valves, to cut the boiler in on the line, the steam pressure on the incoming boiler should be: slightly lower than line pressure . Exam 2 Steam Boilers & Fittings
Eric's graph indicates "gauge pressure". When you use the steam tables, you have to add "atmospheric pressure" (Patm) to "gauge pressure" (Pg) to get "absolute pressure" or P. Adding 1 bar at sea level is about right. 1 bar = 0.987 atmosphere = 29.53 inches of mercury To be precise about it, add the atmospheric pressure (as reported by the
turned boiler off and closed fresh water feed to expansion tank pressure was about 32 psi and stayed there for 2 hours left fresh water feed to indirect water heater open. water pressure from well does not exceed 72 psi when I turned boiler on pressure rose to 35psi and back down to 30 psi while temp rose to 175 and then shut off and cools down
First off, the boiler I'm speaking of is in my 3 family home. The house was heated with one steam system. I removed all of the radiators and pipes and installed 3 separate hot water (baseboard) systems in it's place. The steam boiler was converted for hot water use and is now used for the 1st floor apartment. It's a Weil McLain "Gold" Oil-Fired
If a boiler has reached 220°F, a sudden drop in pressure could cause the tank to burst. Overheating also is the main cause of leaking. When the water temperature in the boiler becomes too high, it increases the water pressure throughout the system. This will cause breaks to begin occurring at …