industrial gas boiler tripping

Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

Combi Boiler tripping RCD | DIYnot Foru

Oct 16, 2013· Combi Boiler tripping RCD. Discussion in 'Plumbing and Central Heating' started by North, 16 Oct 2013. Page 1 of 2 1 2 Next > North. Joined: 3 Mar 2010 Messages: 245 Thanks Received: 2 Location: Hampshire Country: Yesterday the RCD tripped when I turned the heating on. It never happen before so I checked inside the combi boiler ( a Glow worm

Boiler tripping on overheat | DIYnot Foru

User rating: 5/5 Sep 03, 2019· Hi, hopefully I can get some advice. My central heating boiler, Potterton Prima Profile 60E, keeps tripping on overheat. This is very regular, a lot of mornings the heating isn’t on because it tripped the night before.

4 Reasons Why Your Furnace Can Trip the Circuit Break

4 Reasons Why Your Furnace Can Trip the Circuit Breaker. Posted 12-18-15 in Heating. So you just had to reset the circuit breaker for your furnace. And now you’re wondering what caused this to happen. If your furnace is tripping your circuit breaker or you have another heating problem, contact us today. Join our email newsletter.

High limit stat tripping on a warmflow oil boil

Oct 27, 2018· Good evening, about 2 years ago a customers high limit stat was tripping every so ofte,n not a sealed system. I turned the circulating pump speed up to 3 from 2 and seemed to cure it , until recently. Tripping again and hes now saying when he turned the Boiler on didn't heat water but rads were hotter than normal.

Industrial Gas Boilers Tripping - Concours de carto

Industrial Electric Boiler Proposal. 2011-1-21 · industrial boilers (71%) are located at facilities in the food, paper, chemicals, refining and primary metals industries. Almost 78 percent of all boiler units use natural gas as a fuel. 56 percent of industrial boiler capacity is natural gas-fired, although certain industries (refining, Get a Quote

Rollout thermal fuse on boiler keeps tripping, should

Nov 20, 2016· He reset it and the boiler fired up. He left. Well since then the rollout keep tripping off. Could it be the fuse needs replacing? The gas line was replace the day before (black pipe was replaced with copper line by a professional). This started yesterday morning or late Friday night. The boiler will run for about 15 minutes then the rollout trips.

Industrial boiler technology for beginne

How an industrial boiler system works The heart of an industrial boiler system is a hot water or steam boiler operated with a certain kind of fuel. The boiler heats up or evaporates the water inside it, which is then transported to the consumers via pipe systems. In case of hot water the transport energy is …

Industrial Gas Boilers Tripping - Bhartii

Free Online Consultation; boiler tripping electric - kuurnsezichten.be. Why your boiler is tripping electricity DHS Heating Bristol. boiler advice, boiler fault, boiler repair, RCD switch, tripping the electric 0 Comment If you're finding that your combination boiler keeps tripping the RCD switch on your fuse board and tripping the electricity, it could be a sign of a fault or leak within your

Boiler fault and rcd tripping? | ElectriciansForums.n

Boiler keeps cutting out | Screwfix Community ForumMar 16, 2020Overheating Ideal Classic boiler | Screwfix Community ForumDec 20, 2019Boiler overheat cut-out: Blockage or boiler faultFeb 10, 2018boiler tripping RCD | Screwfix Community ForumDec 29, 2009See more results Feb 20, 2018· I got called out to house a few days ago with the main rcd tripping when they turned the hot tap on with the combi firing up.They had only just had the new boiler fitted and the tripping had started straight after it was installed.

Why your boiler is tripping electricity | DHS Heating Brist

Wiring between the boiler and outside . If your boiler keeps tripping the electricity, it’s always best to enlist the help of a professional heating engineer. A Gas-safe engineer will be able to assess the situation and carry out boiler repairs or replace parts that could be damaging your system.

Boiler Tripping RCD | Screwfix Community For

Mar 25, 2015· Boiler Tripping RCD. Discussion in 'Plumbers' Talk' started by Hadventure, Nov 19, 2012. Page 1 of 2 1 2 Next > Hadventure Member. We then tried setting the programmer again when the gas fitter who fitted and services the boiler was here and surprise surprise it did not do it. but today i left the hot water on longer than I usually do and

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch