Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

Galaxy Natural Gas Steam Boiler with - The Home Dep

The Slant/Fin Natural Gas Steam Boiler 120,000 BTU Input 73,000 BTU Output 304 Sq. Ft. of Steam with Intermittent Electronic Ignition is a perfect choice for long term efficiency and reliability. It is assembled with durable metal push nipples.

Boiler Capacity - Engineering ToolB

Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as

Gas Steam Boilers - eComfo

Crown Boiler Bermuda - 180K BTU - 77.5% Thermal Efficiency - Steam Gas Boiler - Chimney Vent Model: BSI311ENPZZPSU Floor Mounted, Cast Iron Boiler with Single Stage Gas Valve.

How to Correctly Size a Steam Boiler for Your Business | Miu

Even if your boiler system is technically sized to meet your demands at peak capacity, you may end up producing way more steam than you need — especially if you’re using a fire tube boiler in a facility that regularly experiences fluctuating load demands.

Boiler (power generation) - Wikiped

File Size: 1MB A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator.

sizing steam boiler — Heating Help: The Wa

The first floor is a separate apartment and has its own steam boiler. My question concerns the boiler sizing. From reading the posts I know it is very important to size a steam boiler based on the connected load. The connected load is 180 square feet steam. There is a boiler rated at 158 square feet steam and the next size is 271 square feet steam.

Boiler Sizing | Weil-McLa

Name Description Boiler Replacement Guide Step-By-Step Procedures For Properly Sizing Hot Water And Steam Replacement Boilers For Homes And Small Commercial Buildings Easy-Loop Booklet Simplified Procedures For Designing An Easy-Loop Hydronic Heating System Using Weil-McLain® Boilers, Convector Baseboard, And Series-Loop Piping

Compact Steam Boil

CMB Low Pressure Steam Generator- Delivers 9 to 45 lbs. of steam per hour at 0 - 90 psig, and is used in many manufacturing processes.The CMB’s small size and small capacity make it an ideal “point of use” steam source in industrial plants, computer rooms, laboratories, hospitals, jewelry stores, steam rooms and other spot heating applications.

capacity of steam boiler,hot water boiler parameters,ste

Capacity and parameters of boiler includes evaporation, pressure, heat capacity, temperature. Evaporation of boilers. During long-term operation of steam boiler continuously, the steam generated per hour is called evaporation of this boiler. The common units of evaporation is t/h.

Boiler Formulas - Johnston Boil

File Size: 881KB Boiler Horsepower What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? The factor of evaporation is 1.08. BHP = (LB/HR*fe)/34.5 BHP Boiler Horsepower BHP = (LB/HR*fe)/34.5 Lb/Hr Pounds per Hour BHP = 21500 * 1.08 / …

Universal TC – Steam Boiler - Certu

Manufactured with a Touch Screen control facility, data from the CERTUSS Universal TC Model generator can be easily forwarded to site BMS via a compatible Profibus / CAN bus, Modbus, BACnet or similar system.Offering a standard Thermal efficiency of > 93%, the CERTUSS Universal TC Model generator is a world leader in comparison to other industrial steam boilers or industrial steam …

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration

Copyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.

top