MENU
products
  1. Home
  2. --
  3. Industrial boilers

conversion of steam boiler in 5 ton to kw

Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

Unit Conversion--How to Calculate Boiler Horsepow

The Boiler Horsepower (BHP) is the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 ℉, with feedwater at 0 Psig and 212 ℉. “Boiler horsepower, a unit of measurement of power of steam boilers” from Wiki.

CONVERSION OF BOILER IN KG/H AND KW - cni.co.

CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 15.65 78

Kilowatts to Boiler Horsepower Conversion (kW to BH

Convert kilowatts to boiler horsepower (kW to BHP), please type the kilowatts value, select the precision value and press the convert button below.After the kW conversion completed, the steam engine horsepower (boiler) value displayed below with kilowatts and hp values.

Convert ton to kW - Conversion of Measurement Uni

5 ton to kW = 17.58426 kW. 10 ton to kW = 35.16853 kW. 15 ton to kW = 52.75279 kW. 20 ton to kW = 70.33706 kW. 25 ton to kW = 87.92132 kW. 30 ton to kW = 105.50559 kW. 40 ton to kW = 140.67411 kW. 50 ton to kW = 175.84264 kW. ››.

Refrigeration tons to kilowatts (kW) conversion calculat

kW to tons conversion calculator How to convert tons to kW. One refrigeration ton is equal to 3.5168525 kilowatts: 1 RT = 3.5168525 kW. One kilowatt is equal to 0.284345 refrigeration ton: 1 kW = 0.28434517 RT . So the power P in kilowatts (kW) is equal to the power P in refrigeration tons (RT) times 3.5168525: P (kW) = P (RT) × 3.5168525 . Example

Convert Boiler Horsepower to Kilowatts - Kyle's Convert

5 Boiler Horsepower to Kilowatts = 49.0533: 200 Boiler Horsepower to Kilowatts = 1962.1314: 6 Boiler Horsepower to Kilowatts = 58.8639: 300 Boiler Horsepower to Kilowatts = 2943.1971: 7 Boiler Horsepower to Kilowatts = 68.6746: 400 Boiler Horsepower to Kilowatts = 3924.2628: 8 Boiler Horsepower to Kilowatts = 78.4853

Boiler horsepower to kilowatts [BHP to kW] conversion tabl

How to convert boiler horsepower to kilowatts [BHP to kW]: P kW = 9.81055407 × P BHP. How many kilowatts in a boiler horsepower: If P BHP = 1 then. P kW = 9.81055407 × 1 = 9.81055407 kW. How many kilowatts in 98 boiler horsepower: If P BHP = 98 then. P kW = 9.81055407 × 98 = 961.43429886 kW.

boiler steam production conversion ton hr to kw – o

Conversion Factors ; Energy: 1 1 boiler horsepower (BHP) = 33520 BTU/hr 1 boiler horsepower (BHP) = 9803 Watts 1 lb/mmbtu = 1.548 kg/MW-hr 1 lb steam/hr (300 psi. Boiler Capacity Steam boilers output can be expressed in Boiler Horsepower, W = boiler capacity (Btu/h, kW) Lbs of Steam to Boiler Horsepower Conversion.

Boiler Capacity - Engineering ToolB

Horsepower (hp) can be converted into lbs of steam by multiplying hp with 34.5. Example - Boiler Horsepower to lbs of Steam Conversion. 200 hp x 34.5 = 6900 lbs of steam per hour. Lbs of steam can be converted to hp by dividing lbs steam per hour by 34.5. Example - Lbs of Steam to Boiler Horsepower Conversion. 5000 lbs of steam / 34.5 = 145 hp

Converter Tons to Kilowat

The ton (ton of refrigeration) is a unit of power. This tool converts tons to kilowatts (ton to kw) and vice versa. 1 ton ≈ 3.5169 kilowatts. The user must fill one of the two fields and the conversion will become automatically. 1 tons = 3.5169 kilowatts Formula tons in kilowatts (ton in kw).

How to Convert Steam to BTU | Scienci

For the low-pressure steam typically used in heating systems, that ratio is 1,194 BTUs for every pound of steam the system provides. If your boiler supplies 400 pounds of steam per hour, for example, you would multiply 400 pounds by 1,194 to arrive at a figure of 477,600 BTUs.

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration

Copyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.

top